Applications

Concentration and drying of pharmaceutical wastewater

Concentration and drying of pharmaceutical wastewater

Concentration and drying of pharmaceutical wastewater

● Industry: Traditional Chinese Medicine Extraction

● Raw liquid: 50 tons/day, with a salt content of 1%

● Evaporation medium: Water

Alternative Plan: MVR-2000 with Dryer

● Falling-film evaporator, single-stage compressor,耙式 dryer

● Designed for an evaporation capacity of 2 t/h, the actual evaporation capacity can reach up to 3.2 t/h.

Operating energy consumption

● MVR operation power consumption: 64 kW; dryer operation power consumption: 10 kW

● Steam consumption: 320 kg/h