Working Principle of the Roots Pump-Water Ring Vacuum Unit
Working Principle of Roots Pump-Water Ring Pump Vacuum Unit
Roots vacuum pumps (mechanical booster pumps) designed for higher vacuum levels cannot be directly vented to the atmosphere. If such direct venting were permitted, the pressure difference between the suction and discharge ports of the Roots vacuum pump would become excessively large, causing the pump to overload. Simply increasing the motor power of the Roots vacuum pump would only lead to overheating, causing the tiny clearance between the rotor blades to quickly become jammed due to thermal expansion. To ensure that the Roots vacuum pump can achieve a higher vacuum level, it is essential to maintain the proper clearance between its rotor blades. Therefore, when using a Roots vacuum pump, it is mandatory to install a preliminary pump. The preliminary pump should first reduce the system pressure to a certain range before the Roots vacuum pump is started. This approach effectively prevents the Roots vacuum pump from overloading. As for the preliminary pump, you can choose from various types of vacuum pumps that are capable of direct atmospheric venting, such as liquid-ring vacuum pumps, rotary vane vacuum pumps, slide-valve vacuum pumps, or reciprocating vacuum pumps.
In general, when selecting a vacuum unit with Roots pumps, using a liquid-ring pump as the forepump is more advantageous than using other types of vacuum pumps. This is mainly because the liquid-ring pump can effectively remove large quantities of condensable vapors—especially when the gas-sealed mechanical vacuum pump equipped with oil seals lacks sufficient capacity to handle condensable vapors, or when the solvents used can degrade the pump oil and impair performance, or when the vacuum system cannot tolerate oil contamination.
Roots pumps–liquid-ring pump units are widely used in vacuum systems for applications such as chemical engineering, food sublimation drying, and high-altitude simulation tests. These combined units generally come in the following types.

(1) Roots pump-water ring pump: In this unit, the water ring pump serves to create the preliminary vacuum required by the Roots pump. Therefore, the maximum allowable exhaust pressure of the water ring pump must be carefully considered—on the one hand, we should strive to maximize the ultimate vacuum of the water ring pump; on the other hand, we must also find ways to increase the maximum allowable exhaust pressure of the Roots pump.
Generally speaking, single-stage liquid-ring pumps have relatively low ultimate vacuum levels. However, the pre-vacuum requirements for Roots pumps currently manufactured in China are relatively high. Therefore, in practice, single-stage liquid-ring pumps are not used as the forepump for Roots pumps; instead, double-stage liquid-ring pumps—whose ability to achieve higher ultimate vacuum levels makes them more suitable—are employed as forepumps. Moreover, using a double-stage liquid-ring pump can further enhance the overall system's ultimate vacuum level.
The ultimate vacuum level of a Roots pump is relatively low, especially when it is operated in combination with a liquid-ring pump, which limits its application range and may further reduce the overall system’s ultimate vacuum level. However, if two Roots pumps are connected in series and then combined with a liquid-ring pump, the system’s ultimate vacuum level can be significantly improved.
Therefore, in this type of configuration, it is common to see two Roots pumps connected in series, followed by a two-stage liquid-ring pump serving as the forepump. See Figure 1 Form a crew.
(2) Roots pump—liquid-ring pump—atmospheric pump unit: Even when using a two-stage liquid-ring pump, the improvement in ultimate vacuum level is limited to a certain range, owing to the constraint imposed by the saturation vapor pressure of water. The theoretical limit pressure of a liquid-ring pump is precisely the saturation vapor pressure of water. However, taking into account factors such as gas backflow, the actual ultimate pressure of a liquid-ring pump is significantly higher than the saturation vapor pressure at that water temperature. To further enhance the ultimate vacuum level of the forepump, the liquid-ring pump can also be used in combination with an atmospheric pump.

See Figure 2. In this way, after connecting a single-stage atmospheric pump in series, the ultimate vacuum can reach 20–30 Torr. If a liquid-ring pump is combined with a two-stage atmospheric pump, the ultimate vacuum can even reach 2–10 Torr.
(3) Roots pump-water ring pump parallel mechanical vacuum pump: This unit is primarily used in vacuum systems that require handling large amounts of water vapor and demand high ultimate vacuum levels, such as in vacuum drying applications.
In vacuum systems that handle large volumes of steam, water-ring pumps are relatively suitable. However, due to their relatively low ultimate vacuum level, the overall system’s ultimate vacuum is also limited. Although mechanical vacuum pumps with higher ultimate vacuum levels are required as forepumps in vacuum systems demanding higher vacuum degrees, water-ring pumps consume a great deal of power, have low efficiency, and generate high noise levels. Therefore, using a water-ring pump as a forepump for a Roots pump in vacuum drying systems that require prolonged operation is economically inefficient.
Under the above circumstances, a gas-boosted mechanical vacuum pump can be connected in parallel with a liquid-ring pump to serve as a forepump for a Roots pump. During vacuum drying, first use the liquid-ring pump for preliminary evacuation until the amount of water vapor has significantly decreased; then start the gas-boosted mechanical vacuum pump and shut down the liquid-ring pump. In cases where drying takes a relatively long time, both the cooling water requirement and power consumption will be lower. For example: Figure 3 As shown.

Operation of the Roots Pump-Water Ring Pump Unit
(1) Install a condenser upstream of the unit.
To minimize the size of the pump unit as much as possible, one can arrange for the steam to be condensed before it enters the pump unit. This leaves behind only non-condensable gases and trace amounts of residual vapor. After the gas is cooled, its volume also decreases at the same pressure. Consequently, the required pumping capacity is reduced after condensation, allowing the pump itself to be smaller accordingly.
Which method is more cost-effective? It depends on the specific circumstances. Here’s an example:
There are two ways to condense steam: one is to install a cooling device, and the other is to equip the high-pressure stage of the unit with a condenser that can be cooled using ordinary water.
The system needs to remove 50 kg of water vapor per hour, with a volumetric flow rate of 50,000 m³/h at an inlet pressure of 1 Torr.
1) To extract the aforementioned amount of water vapor, a three-stage Roots pump system connected in series, with a liquid-ring pump serving as the forepump, is required. The total power of this unit is 90 kW.
2) To ensure that the steam condenses before reaching the vacuum pump, a condenser and a cooling unit with a capacity of 30,000 kcal/h should be installed at location A, as shown below: Figure 4 As shown, at an inlet pressure of 1 Torr, the condensation temperature of water vapor is uniformly -19℃. To ensure continuous operation, the condensation temperature of the condensing unit should be set at -25℃, and two condensers should be installed in parallel. Based on the composition of the non-condensable gases, the pumping capacity of the vacuum pump can be reduced to between 1,000 and 2,000 m³/h. The total power consumption of the entire unit (including the power consumed by the condensers) remains at 90 kW.
3) First, use a Roots pump to extract the water vapor and then condense it at a pressure of 45 Torr. At this pressure, the condensation temperature is approximately 36℃, allowing the condenser's condensation temperature to be maintained between 30 and 35℃, which can be effectively cooled using ordinary cooling water. The condenser is located at point B. At this stage, the total power consumption is around 75 kW.
As shown by the comparison of the three approaches mentioned above, the third option is the best, as it can reduce power consumption by 15 kW.
In summary, after water vapor is cooled, only non-condensable gases remain. At very low pressures, the specific volume of water vapor is quite large; once these condensable vapors have condensed, the pumping capacity required by the pump is significantly reduced. Moreover, regardless of whether the vapor has condensed or not, at the same pressure, any reduction in gas temperature will lead to a decrease in volumetric flow rate. For example, in chemical processes, gases at temperatures ranging from 200 to 300°C are not uncommon. If such a gas is cooled from 300°C down to 50°C, the volume of dry air will decrease by approximately 45%. This allows us to select a vacuum pump unit with a smaller capacity.
(2) Operating sequence of the unit:
1) When the unit is equipped without a bypass valve, first start the liquid-ring pump. The gas from the system being evacuated enters the liquid-ring pump via the roots pump (the gas drives the roots pump rotor to rotate on its own, much like a flow meter), and then is discharged into the atmosphere. Once the suction pressure of the liquid-ring pump (or, if an atmospheric pump is connected in series, the suction pressure of the atmospheric pump) reaches the initially specified value for the roots pump (i.e., the allowable exhaust pressure), only then should the roots pump be started, at which point the unit will officially begin operation and start working.
2) When the unit is equipped with a bypass valve, such as... Figure 5 As shown, first start the liquid-ring pump, then activate the Roots pump. At this point, since the pressure difference between the inlet and outlet of the Roots pump is relatively large, the bypass valve automatically opens. Part of the gas from the vessel being evacuated flows through the bypass valve into the liquid-ring pump, while the remaining portion, under the action of the Roots pump, also enters the liquid-ring pump via the pump itself. Clearly, this increases the pumping speed, allowing the system to quickly reach the pre-vacuum state required by the Roots pump, at which point the pressure difference between the inlet and outlet becomes smaller. The bypass valve then automatically closes (or can be closed manually), and the unit begins formal operation. This method significantly shortens the pre-evacuation time, but it does require more complex equipment.

(3) Relationship between the performance of the unit, Roots pump, and forepump
The performance of the unit is closely related to the performance of the Roots pump, and the performance of the Roots pump itself varies depending on the type of preceding pump.
1) Since there is a clearance between the rotors of a Roots pump and between the rotors and the casing, backflow occurs. This backflow is influenced by both the inlet pressure and the outlet pressure. Even for the same Roots pump, its pumping speed will vary depending on the type of forepump used.
The pumping speed of a Roots pump can be determined by the following formula:
δ=δ 0 (P 2/P1 /K)
In the formula: δ 0 - Designed pumping rate;
P1 - Inlet pressure;
P2 - Outlet pressure;
K is a pump-specific constant, determined by the shape of the pump rotor, the clearance between components, the circumferential velocity of the rotor, and the outlet pressure.
As shown in the above equation, the pumping capacity is influenced by the ratio of the outlet pressure to the inlet pressure. In other words, if the pumping speed of the preceding pump is increased, the pumping speed of the Roots pump will also increase.
(2) The ultimate pressure is determined by the pump’s pumping speed, the backflow rates through each gap, the leakage from the pump body, and the outgassing rate on the high-vacuum side. That is:
P0=(Q 1 +Q 2 +Q 3 )/δ In the formula: P0 – ultimate pressure;
δ- Pumping speed;
Q 1 - Return flow;
Q 2 - Leakage amount;
Q 3 - Air release volume.
Among these parameters, Q1 is greatly influenced by the exhaust pressure, which in turn is affected by the ultimate pressure of the preceding pump. When a liquid-ring pump is used as the preceding pump, the ultimate pressure of the Roots pump varies depending on the saturation vapor pressure of the liquid ring.
Figure 6 This is a performance comparison when using the same Roots pump with different forepumps.


As shown in the figure, the higher the ultimate vacuum of the preliminary pump, the higher the ultimate vacuum of the entire unit will also be. When two-stage Roots pumps are used in series, the ultimate vacuum of the entire unit can be further improved (essentially, the first Roots pump serves as the preliminary pump for the second Roots pump). Moreover, the performance curve becomes smoother and broader, meaning that the operating range is expanded (as evidenced by comparing curves 1 and 2 with curves 3 and 5). The performance curves of units 1 and 2 are roughly identical. Similarly, the performance curves of units 3, 4, and 5 also share certain similarities. However, the performance curves of units 1 and 2 are entirely different from those of units 3, 4, and 5. This clearly demonstrates that, for the same Roots pump, when different preliminary pumps are selected, the resulting performance curves of the entire unit exhibit fundamental differences. Hence, it is evident that the preliminary pump has a significant impact on the overall performance of the unit.
(4) Selection of liquid-ring pumps
A so-called liquid-ring pump is a type of liquid-ring pump that uses water as the liquid ring. Using water as the liquid ring has many advantages, such as low cost, easy availability, and no environmental pollution. However, it also has a significant drawback: due to water's high saturation vapor pressure, the suction pressure of the liquid-ring pump tends to be relatively high. In such cases, if a liquid with a lower saturation vapor pressure is used instead as the liquid ring, the pump's ultimate vacuum level can be significantly improved. For instance, if a Roots pump in a particular unit has a maximum allowable exhaust pressure of 10 Torr, using water as the liquid ring would require an additional backing pump to serve as the pre-stage pump for that Roots pump. On the other hand, if mineral oil is used as the liquid ring instead, there would be no need for an additional backing pump, thus simplifying the overall system configuration.
(5) Unit performance and allowable discharge pressure of the Roots pump
The performance of the pump unit largely depends on the allowable discharge pressure of the Roots pump. The lower this allowable value is, the less likely it becomes for a liquid-ring pump to serve as a forepump. If the allowable discharge pressure of the Roots pump is between 1 and 10 Torr, and regardless of whether the liquid-ring pump is single-stage or multi-stage, its ultimate pressure will significantly exceed this value. Consequently, it would be impossible to use such a liquid-ring pump alone in combination with the Roots pump; instead, a secondary atmospheric pump would need to be added. However, if the allowable discharge pressure of the Roots pump is above 100 Torr, the preceding liquid-ring pump can itself serve as a forepump for the Roots pump's forepump, thereby greatly expanding the application range of the forepump.
(6) Application Examples
The production process of a certain synthetic fiber product is as follows: low molecular weight—high molecular weight—forming into strips—slicing—drying (using a Roots pump-water ring pump unit for vacuum drying)—spinning—drawing and heating—texturing—finished product.
One of the crucial processes is drying slices measuring 5×5×5 (mm) in size, so that they can be drawn into filaments. Ideally, during the filament-drawing process, the moisture content should be zero. However, since this ideal condition cannot be achieved in practice, the moisture content must be kept below 0.02%. If the moisture content exceeds this requirement, drawing filaments under high temperature and high pressure would cause the polymer to decompose, thereby compromising the strength of the final product.
The vacuum system setup for the Roots pump-water ring pump unit used in the drying process is shown in Figure 7. The technical parameters of each pump in the unit are listed in the table below.
|
Name
|
Pumping rate
(m³/h) |
Rotor diameter
(mm) |
Rotational speed
(revolutions per minute) |
Matching power
(kW) |
|
Roots pump 1
|
400
|
160
|
1450
|
2.2
|
|
Roots pump 2
|
200
|
102
|
2900
|
1.3
|
|
Two-stage liquid ring pump
|
100
|
The impeller of the preceding stage is half the size of that of the following stage.
|
1450
|
5.5
|

The functions of the main equipment are briefly described as follows:
(1) Vacuum valve
Close the vacuum valve, and the unit will stop running, allowing the drying system to maintain a certain degree of vacuum.
(2) Automatic pneumatic safety valve
To prevent water from the water-ring pump system from flowing back into the Roots pump and the vacuum drying system when the unit suddenly shuts down.
(3) Differential pressure valve
When the unit starts operating, first start the liquid-ring pump. As a pressure differential gradually builds up across the differential-pressure valve, once it reaches a certain value, the valve automatically opens, allowing most of the gas in the system to flow through this valve into the liquid-ring pump. As atmospheric air gradually flows into the liquid-ring pump via the atmospheric pump, the pressure difference across the differential-pressure valve gradually decreases, eventually causing the valve to close. Consequently, the atmospheric pump immediately begins its normal operation. The purpose of the differential-pressure valve is to shorten the pre-pumping time required before the atmospheric pump can operate normally.
(4) Water level gauge
The check valve prevents backflow of water from the liquid ring pump.
The operational sequence is as follows: First, start the liquid-ring pump. Gas in the system flows from the Roots pump (which at this point drives the Roots pump rotor to rotate) into the liquid-ring pump and is then discharged into the atmosphere via the gas-water separator. When the pressure drops to an absolute pressure of 50 Torr, start Roots pump 2; when the absolute pressure reaches 20 Torr, start Roots pump 1. Finally, the system pressure can be reduced to 0.088 Torr, and under normal circumstances, it can be maintained below 1 Torr.
For the performance parameters of the Roots-water ring vacuum unit, please refer to: