The working principle of a Roots vacuum pump
The structure of a Roots pump is shown in the figure. Inside the pump chamber, two “8”-shaped rotors are mounted perpendicularly on a pair of parallel shafts and driven by a set of gears with a transmission ratio of 1, causing them to rotate synchronously in opposite directions. A certain clearance is maintained between the rotors themselves as well as between the rotors and the inner wall of the pump casing, enabling the pump to operate at high speeds. Since the Roots pump is a vacuum pump without internal compression, its compression ratio is typically very low; therefore, high- and medium-vacuum applications usually require a preliminary pump. The ultimate vacuum achievable by a Roots pump depends not only on the pump’s own structural design and manufacturing accuracy but also on the ultimate vacuum of the preceding pump. To further improve the pump’s ultimate vacuum, Roots pumps can be used in series.
The working principle of a Roots pump is similar to that of a Roots blower. As the rotors continuously rotate, the gas being pumped is drawn in through the intake port into the space v0 between the rotors and the pump casing, and then discharged through the exhaust port. Since the space v0 is completely sealed after gas intake, there is no compression or expansion of the gas within the pump cavity. However, when the top of the rotor passes over the edge of the exhaust port and the space v0 becomes connected to the exhaust side, the higher pressure of the gas on the exhaust side causes a portion of the gas to flow back into the space v0, abruptly increasing the gas pressure. As the rotor continues to turn, the gas is finally expelled from the pump.
The figure below illustrates the pumping process of a Roots pump rotor as it rotates from 0° to 180°. At the 0° position (Figure a), the left rotor seals a volume of gas, v0, at the pump inlet. As the rotor turns to the position shown in Figure b, this chamber communicates with the exhaust port. Due to the higher pressure on the exhaust side, some of the gas flows back toward the intake side. When the rotor reaches the 90° position (Figure d), the gas sealed by the left rotor, together with the backflowing gas, is discharged outward through the pump. At this point, the right rotor also begins to seal a volume of gas, v0, at the pump inlet. As the rotor continues to rotate to the position shown in Figure e, the gas sealed by the right rotor communicates with the exhaust port, and the above-mentioned process repeats itself. In total, during one full rotation of the rotor’s main shaft, four volumes of gas, each equal to v0, are discharged.
A 3D demonstration of the working principle of a Roots pump