Working Principle of Air-Cooled Roots Vacuum Pump
The structure of the ZJQ series air-cooled Roots vacuum pump is shown in the figure. Inside the pump chamber, two rotors (with two or more lobes) are mounted on a pair of parallel shafts and driven by a set of gears with a transmission ratio of 1, causing them to rotate synchronously in opposite directions. A certain clearance is maintained between the rotors themselves as well as between the rotors and the inner wall of the pump casing, enabling the pump to operate at high speeds. Compared with the conventional ZJ series Roots vacuum pumps, the ZJQ series air-cooled Roots vacuum pump features return ports designed at appropriate locations on the side of the pump body. These ports direct cooled gas into the pump chamber to cool the rotors, thereby keeping the rotor temperature within the specified range. As a result, the ZJQ series air-cooled Roots vacuum pump can withstand higher pressure differentials (up to 90 kPa) without overheating.
Working Principle of Air-Cooled Roots Vacuum Pump
Figures (a) through (f) illustrate the working process of the ZJQ air-cooled Roots vacuum pump:
As shown in Figure (a), during rotation, the cavity above the pump gradually expands, drawing gas into it. When the rotor reaches the position shown in Figure (b), the right rotor seals a volume V0 of gas at the pump inlet. As the rotor continues to rotate to the position shown in Figure (c), the right-side V0 cavity connects with the return pipeline. At this point, since the pressure on the exhaust side is higher than that in the V0 cavity, the exhaust gas—after being cooled by the heat exchanger—is returned to the V0 cavity. When the rotor rotates further to the position shown in Figure (d), the left rotor seals another volume V0 of gas. As the rotor moves to Figures (e) and (f), the left-side V0 cavity connects with the return pipeline, and the cooled gas is returned to the left-side V0 cavity. When the rotor continues to rotate back to Figure (a), the return cavity on the right side becomes connected with the exhaust port. As the rotor continues to rotate to Figure (c), the gas initially sealed by the right rotor, together with the returning gas, is discharged from the pump. In one complete rotation of the rotor’s main shaft, a total of six volumes V0 of gas are discharged.